FASEC 53, Instrukcje, ELIWELL

[ Pobierz całość w formacie PDF ]
FASEC 53
manual speed controller
WHAT IT IS
GENERAL DESCRIPTION
FASEC 53 is designed for speed control
and is particularly suitable for fan applica-
tions.
The standard version provides a triac out-
put to control a load up to 2.5 A, while a
special version ensures control up to 7 A.
The latter version contemplates the use of
an LC filter fitted outside the instrument.
Such filter is necessary to reduce conduct-
ed emissions and radio frequency due to
the type of regulation.
On its frontside a regulation knob is avail-
able to change the speed within the range
0…100% with the possibility to set a mini-
mum value.
Another special model is available to con-
trol speed in ZHIEL motors.
for correct operation is from –5 to 65 °C.
Do not install the instrument in moist
and/or dirty places or near heat sources.
The external filter (for the version with 7 A
capacity) is provided with a bolt for fixing.
FASEC 53 is designed for speed
control and is particularly suitable
for fan applications.
ALLOWED USE
For your safety, FASEC 53 should be in-
stalled and used according to the given in-
structions and, especially, no components
subject to dangerous voltage must be ac-
cessible under normal conditions: the only
accessible part must be the front of the in-
strument.
This device should be adequately protect-
ed from water and dust considering its ap-
plication. Its rear side should only be
accessible by using a tool.
Work on electrical connections always with
the machine turned off.
FASEC 53 is suitable to be incorporated in
household appliances and/or the like, and
it has been tested -as regards its safety- to
the reference European Harmonised
Standards.
HOW IT IS MADE
• Size: front panel 48x96 mm, depth
96 mm (excluding socket)
• Mounting: panel mount on hole
45x92 mm
• Connections: Octal socket
• Regulation: by knob on the
frontside
• Regulation output: 2.5 A TRIAC,
7 A TRIAC
• Filter external (in version 7 A):
maximum current for load supply
7 A; cylinder size ø 38 mm, height
28 mm; fixing bolt M8
• Regulation type: phase choking
proportional
• Power supply: 230 V
MECHANICAL MOUNT
The instrument is designed for panel
mount. Drill a 45x92 mm hole and insert
the instrument holding it with the special
brackets supplied.
The operating temperature range allowed
A
, 50 Hz.
CONNECTIONS
6 5 4 3
blue
FILTER
blue
FASEC 53 7A
(octal socket)
black
white
brown
load
POWER SUPPLY
brown
7 8 1 2
6 5 4 3
FASEC 53 2,5A
(octal socket)
7 8 1 2
POWER SUPPLY
load
It is rated:
• according to is construction, as an auto-
matic, electronic control device to be in-
corporated, independently installable
• according to its automatic operation fea-
tures, as a 1Y-type acting control device
or suggested by common sense due to
evident safety reasons, must be carried
out outside the instrument.
Connections
: Octal socket.
Operating temperature
: –5…65 °C;
(23…149 °F).
Storage temperature
: –30…75 °C;
(–22…167 °F).
Regulation
: 0…100%, by regulation knob
on the frontside.
Regulation output
: 2.5 A TRIAC, 7 A TRI-
AC.
Filter external
(in version 7 A): maximum
current for load supply 7 A; cylinder size
Ø 38 mm, height 28 mm; fixing bolt M8.
Regulation type
: phase choking propor-
tional.
Power supply
: 230 V
LIABILITY AND RESIDUAL RISKS
Invensys Controls Italy s.r.l. is not liable for
any damages caused by:
- installing or using this instrument in a dif-
ferent way than it was designed for, and in
particular, without complying with the safe-
ty prescriptions provided for by regulations
and/or hereby stated;
- using it on equipment which does not en-
sure an adequate protection from electrical
shock, water or dust considering the way it
has been installed;
- using it on equipment which allows ac-
cessing dangerous components without
using any tools;
- tampering with the product or altering it;
- using it on equipment which does not
comply with legal provisions and regula-
tions in force.
FORBIDDEN USE
Any use different from the allowed one is,
as a matter of fact, forbidden.
We remind you that the effected regulation
has a functional value, and it is subject to
failure: any protective device provided for
by the regulations concerning this product
a
±10%; 50 Hz.
Invensys Controls Italy s.r.l
via dell'Industria, 15 Zona Industriale Paludi
32010 Pieve d'Alpago (BL) ITALY
Telephone +39 0437 986111
Facsimile +39 0437 989066
Internet http:/www.climate-eu.invensys.com
DISCLAIMER
This manual and its contents remain the
sole property of Invensys Controls Italy
s.r.l., and shall not be reproduced or dis-
tributed without authorization. Although
great care has been exercised in the
preparation of this document, Invensys
Controls Italy s.r.l., its employees or its
vendors, cannot accept any liability what-
soever connected with its use. Invensys
Controls Italy s.r.l. reserves the right to
make any changes or improvements with-
out prior notice.
TECHNICAL DATA
Housing
: plastic, self-extinguishing (NO-
RYL).
Size
: front panel 48x96 mm, depth 96 mm
(excluding socket).
Mounting
: panel mount on hole
45x92 mm.
3/2002 ing
cod. 9IS41008
FASEC 53 3/2002 ing
2
[ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • materaceopole.pev.pl






  • Formularz

    POst

    Post*

    **Add some explanations if needed